Automatic ventilator for adult and paediatric patients
Trolley with handles, 4 antistatic swivel castors and 2 brakes
Designed for frequent and easy dismount and disinfection with
hospital-grade products
Electrical medical air compressor, electronically controlled
Air/O2 mixer
Humidifier
Patient selection: adult and paediatric
Ventilation modes (minimum set, additional modes may be provided by the
available ventilator model):
Pressure controlled (PCV)
Volume controlled (VCV)
Volume Target Pressure controlled (VTPC) or Pressure Regulated Volume
control/guaranteed (PRVC)
Controlled Mandatory ventilation (CMV)
Synchronised Intermittent Mandatory, Pressure and Volume controlled
(P-SIMV and V-SIMV)
Pressure Support modes, including Continuous Positive Airway Pressure
(CPAP) and Intermittent Positive Pressure (IPPV)
Bi-level modes, depending on the available ventilator model
Spontaneous
Not Invasive
Manual
Controls and settings:
Positive End Expiration Pressure (PEEP) 0 – 50 cmH2O, with settings for
paediatric and adult patients
Pressure Support 0 – 70 cmH2O
Tidal Volume 20 – 2,000 ml with settings for paediatric and adult
patients
Frequency 5 – 100 bpm with settings for paediatric and adult patients
I/E ratio 1:10 – 4:1
Inspiratory Flow 1 – 160 l/min with settings for adult and paediatric
patients
Inspiratory Time 0.1 – 9.6 s
Trigger I: Pressure trigger -20 – 0 cmH2O; Flow trigger 0.5 – 15 l/min
Trigger E: 5 – 50 %
FiO2: 21 – 100 %
Air filter capacity at inlet: 99 % > 0.5 micron
Reusable, removable and disinfectable expiration valve/flow sensor.
Safety pressure release valve
Monitored and measured parameters: I:E, Ti, Te, Tidal Volume Vti and
Vte, Minute Volume, Frequency, Insp. and Exp. Pressure and Flow, PEEP,
FiO2, Compliance, Resistance
Curves (waveforms): Pressure – Time, Flow – Time, Volume – Time
Loops: Pressure – Volume, Flow – Volume, Pressure – Flow
Trends and system log storage
Audio and visual alarms: multilevel, Pressure (H/L), Frequency (H/L),
expired Tidal and Minute Volume (H/L), FiO2, PEEP, Apnoea, patient
circuit disconnection and leakage, O2 and Air supply, AC and battery
power, system status, service/maintenance
Display (colour flat panel) showing operational status, set and measured
parameters and values, waveforms and alarms/errors (ventilation
parameters, power and system events)
Self-diagnosis and integrity testing, with live system monitoring
Adjustable patient-circuit support arm
Built-in rechargeable battery, autonomy > 1 hour
Automatic switch to battery in case of power failure, automatic recharge
on connection to mains
Power requirements 110 – 220 V / 50 – 60 Hz
Power consumption 600 – 800 W (depending on the available model)